| Model | MJ050V | MJ200V | MJ500V | MJ1000V | |
|---|---|---|---|---|---|
| Diagram number | MD0000320 | MD0000330 | MD0000340 | MD0000350 | |
| *1 | Rated tension (N) | 50 | 200 | 500 | 1000 |
| *1,4,5 | Maximum roll load (N) | 200 | 200 | 500 | 1000 |
| *1,4 | Maximum overload | 700 | 2000 | 5000 | 10000 |
| Roll displacement (μm·N) | 0.36 | 0.12 | 0.05 | 0.03 | |
| *2 | Resonance frequency (Hz) | 105.0 | 143.8 | 140.9 | 128.6 |
| Frequency response (Hz) | 300 | ||||
| *3 | Main unit mass (kg) | 0.9 | 1.7 | ||
| Direction of resultant tension force | Forward or reverse | ||||
| Mounting angle | Any desired angle | ||||
| Supply voltage | ±15VDC ±1V (+15V/50mA, -15V/10mA) | ||||
| Ambient temperature/humidity | 0 to +50°C, 35 to 85%RH (No condensation permitted) | ||||
| IP Protection Rating | IP30 | ||||
| Notes: *1. The figures for rated tension, maximum roll load, and maximum overload are for double-sided detection. For single-sided detection the above figures should be halved. *2. The resonance frequency figures are for the tension load during double-sided detection and at maximum roll load. *3. The frequency response figure is with respect to a change of 1/10 in the rated tension. *4. For the MJ050, the maximum roll load is not equal to the rated tension (double-sided load). The maximum roll load is 200 N. Consequently, the maximum overload = the rated tension × 10 + the maximum roll load. *5. The maximum overload represents the maximum value of the force exerted in the direction of the resultant force. |
|||||