With its wide variety of options and models, this pyrometer series offers unmatched versatility, whether you require a two-colour (ratio) or one-colour (spectral) measuring technique. Features include: through-the-less sighting, laser target marker, or video camera. Signal processing options include analogue output, digital interface or Profibus DP.
| Measurement parameters |
| Measuring range |
0 - 1000 °C |
| Sensor |
Thin-film thermopile |
| Spectral range |
8 - 14 µm |
| Response time t90 |
≤ 100 ms |
| Measurement uncertainty |
1 % of temp. reading [°C], min. 2 K |
| Repeatability |
1 K |
| Temperature coefficient |
0.1 K/K (T < 200 °C)
0.05 %/K (T > 200 °C) |
| Resolution interface |
≤ 0.5 K |
| Optical variants |
| Lenses |
Standard lens PZ focusing 0.3 m - ∞
Close-up lens PZ 10.05: focusing 0.15 m - 0.3 m |
| Electrical parameters |
| Analog output |
0(4) - 20 mA linear, switchable, scalable |
| Resistance |
≤ 500 Ω |
| Interface |
Profibus DP |
| Power supply |
22 - 27 VDC |
| Current consumption |
≤ 80 mA |
| Features |
| Sighting option |
Through-the-lens-sighting, laser spot light |
| General parameters |
| Connection |
Screw terminals |
| Ambient temperature |
0 - 60 °C |
| Storage temperature |
-20 - +70 °C |
| Permissible humidity |
95 % r.H. max. (non-condensing) |
| Dimension |
Ø 65 mm x 180 mm |
| Housing |
Aluminium |
| Protection class |
IP 65 acc. to DIN 40050 |
| Weight |
approx. 0.5 kg |
| Adjustable parameters |
| Parameters |
Emissivity 10 to 99.9%; increment 0.1 %
Smoothing filter
Min./Max. peak picker
Double maximum with adjustable hold time
Device address
Temperature unit °C/°F
Diagnostic function |
| Functions |
| Overtemperature signal |
if the internal temperature exceeds 65 °C the analog output shows a value > 20.5 mA |
| Scope of delivery |
| |
Pyrometer CellaTemp PZ
Manual
GSD file on CD |